imprimer

Produit

Phoniceram®Phoniceram®

Phoniceram®

The Phonicéram® is a small formatted (up to 295 x 595 mm) single-skined, low thickness (15 mm) terracotta acoustic facing, fi xed to a framework over mineral wool, also existing in a form where it is pre-fitted to the terracotta: Phonicéram® dB.
They are based on Zéphir® cladding. Phonicéram® and Phonicéram® dB are available in ten colours and two perforation designs (14 mm wide), horizontal or vertical (contact us for other designs).

Its strengths

A very good acoustic performance to price ratio. Its acoustic performance, particularly in the area of education for Phonicéram® and in education and office applications for Phonicéram® dB.
The advantages of the Zéphir® system (under Technical approval no. 2/08-1330, see page 19):
  - Its ease of use,
  - a unique visual signature due to its low thickness, to the variety of types of perforation and its two formats that can be used in combination. They may be used in combination with Zéphir® cladding.

Standard dimensions

Product Dimensions Trame de pose Product code Quantité par m² Poids unitaire Poids par m²
Phonicéram® 295 x 595 x 15 300* X 600 PC30PH ou PC30PV 5,6* 4,6 25,8
Phonicéram® 295 x 295 x 15 300* X 300 PC30PH ou PC30PV 11,1* 2,3 25,5
Phonicéram® dB 295 x 595 x 15 300* X 600 PD30PH ou PD30PV 5,6* 4,6 25,8
Phonicéram® dB 295 x 295 x 15 300* X 300 PD30PH ou PD30PV 11,1* 2,3 25,5

Performance

Nuancier


  • Salmon pink

  • Red orange

  • Red

  • Violine

  • Champagne

  • Sahara Beige

  • Chocolate brown

  • Pearl grey

  • Dark grey

  • Ebony

Réalisation

Clinique intersectorielle du groupe hospitalier Paul Guiraud

  • Date du chantier : 2012
  • Localisation : France
  • Architecte (cabinet) : Architecture Studio
  • Type de pose : Pose sur support traditionnel

INSTALLATION

Système de mise en oeuvre

Fixing system

Phonicéram® and Phonicéram® dB are suspended from aluminium rails (Zéphir® rail), supported on a vertical framework of profiles or battens.
For Phonicéram®, the insulation is fitted in the spaces between the vertical framework profiles. For Phonicéram® dB, the 20 mm acoustic insulation, carried by the product itself, performs the acoustic absorption function.
There are various accessories not supplied by TERREAL (in italics in the diagrams): metal or PVC profi les for flashings and various finishes, various screws, fixing anchors, thermal insulation, mastic, fixing brackets and wood or metal framework uprights.

Installation

The Principles for installing Phonicéram® and Phonicéram® dB are the same as for Zéphir®, covered by CSTB Technical approval no. 2/08-1330.
The fitting of the wood or metal profile vertical framework to a concrete or rendered masonry substrate must comply with the rules contained in CSTB specifications nos. 3316/3422/3585, (wooden framework) – or nos. 3194/3586 (metal framework).
Fixing the profiles, using brackets, spaced at between 30 and 90 cm on the outside and up to 120 cm on the inside, depending on the mechanical strength requirements, requires them to be staggered on either side of the upright at a distance appropriate to the situation.

A metal framework based on Z-shape profiles, fixed directly to the support wall, may also be used. Positioned horizontally from the bottom upwards, in line with the spacing indicated on every pallet (theoretical average spacing: 300 mm with standard rail), the rails are fixed to the framework, maintaining a gap of 1 – 2 cm between the ends of rails on the same row.
Phonicéram® or Phonicéram® dB products are then fitted to the rails as work proceeds (from bottom to top), stabilised by two dots of Sikaflex® Pro 11 FC mastic between the product’s lower lug and the upper wing of the rail, adjusting the average vertical joint to 5 mm between products.

At critical points, it is preferable to use Zéphir® which can be cut vertically without difficulty (12 cm minimum) or horizontally (use the intermediate lugs for fixing), using a diamond tipped saw, preferably lubricated with water.

Diagram 1 and 2 : vertical section, running fitting

Diagram 3 : horizontal section, straight run



Diagram 4: horizontal section, straight run

*theoretical dimensions at close tolerances for terracotta

 Constat de Traditionalité 2-08-1330 EN - 1.9 Mo

Constat de Traditionalité 2-08-1330 EN - 1.9 Mo

Acoustic regulation - GB - 240 ko

Acoustic regulation - GB - 240 ko